Updated PDF (New 2023) Actual Huawei H19-338 Exam Questions [Q70-Q92]

Share

Updated PDF (New 2023) Actual Huawei H19-338 Exam Questions

Verified H19-338 Exam Dumps PDF [2023] Access using Exam-Killer


Huawei H19-338 (HCPP-Storage) Exam is an important certification for professionals who work with Huawei storage products and solutions. H19-338 exam covers a wide range of topics related to storage technology and requires a deep understanding of storage architecture, storage networking, data protection, backup and recovery, and storage management. HCPP-Storage certification is internationally recognized and is ideal for individuals who want to advance their careers in the storage industry.

 

NEW QUESTION # 70
Which of the following is not a VDI application scenario in the healthcare industry?

  • A. Telemedicine assistance and training
  • B. Surgical treatment room
  • C. Patient information and management system
  • D. Public terminal

Answer: B


NEW QUESTION # 71
In static-priority arbitration mode, if the active-active relationships are functional, but all replication links between storage arrays are down, what will happen?

  • A. Services stop at the preferred site while they continue at the non-preferred site
  • B. Services continues at both the preferred and non-preferred sites
  • C. Services continues at the preferred site while they stop at the non-preferred site
  • D. Services stop at both the preferred and non-preferred sites

Answer: C


NEW QUESTION # 72
Two quorum devices are deployed at the third-place site.
Both quorum devices can be used for arbitration at the same time.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 73
Which technology can provide real-time service quality visualization and minutes-level fault demarcation?

  • A. TWAMP
  • B. TI-LFA
  • C. BFD
  • D. iFIT

Answer: D

Explanation:
Explanation
iFIT is a technology that can provide real-time service quality visualization and minutes-level fault demarcation. It can collect and analyze network traffic data, identify network problems, and optimize network performance. iFIT uses Telemetry to collect data from network devices, and uses Network Cloud Engine (NCE) to process and display the data. iFIT can also use In-band Network Telemetry (INT) to embed data into packets for more accurate measurement.


NEW QUESTION # 74
Which is the technology used for end-to-end protection of data integrity in the industry?

  • A. SHA
  • B. CRC
  • C. T10 PI

Answer: C


NEW QUESTION # 75
Which Dorado versions or models support Non-Disruptive Upgrade (NDU)? (Multiple choice)

  • A. Dorado V6 entry-level models
  • B. Dorado V6 mid-range models
  • C. Dorado V6 high-end models
  • D. Dorado V3

Answer: A,B,C


NEW QUESTION # 76
Dorado V6 LUNs have controller ownership.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 77
Which of the following is the specifications supported by the RU-5G-101?

  • A. Independent deployment
  • B. 500m POE
  • C. Number of SIMs supported 2 x SIMs

Answer: A

Explanation:
Explanation
RU-5G-101 supports independent deployment. According to the Huawei RU-5G-101 Datasheet2, RU-5G-101 is a high-speed wireless WAN access component that provides 5G wireless broadband access services for enterprises to implement wireless high-bandwidth data transmission. An RU-5G can be deployed independently to provide basic router functions.


NEW QUESTION # 78
Which statements about the SmartTier feature for FS are NOT true? (Multiple choice)

  • A. The migration unit of the FS SmartTier feature is Extent.
  • B. The scope of the SmartTier feature of the FS is a single pool.
  • C. The media in the FS SmartTier feature are divided into three layers SSD, SAS, and NL-SAS.
  • D. The SmartTier features of the FS can define the migration rate.

Answer: A,B,C,D


NEW QUESTION # 79
Which statement about the recommended deployment of the quorum device is true?

  • A. Deploy the quorum device at the third-place site.
  • B. Deploy the quorum device at the non-preferred site.
  • C. Deploy the quorum device at the preferred site.
  • D. Do not deploy the quorum device.

Answer: A


NEW QUESTION # 80
CloudEngine S12700E is a flagship product for Huawei"s CloudCampus Solution- it is designed especially for customers to transform from traditional networks to intelligent, simple experience-centric networks Which of the following statements about the features of CloudEngine S12700E is false?

  • A. CloudEngine SI2700E integrates hardware-based OAM/BFD
  • B. Asingta CloudEngine S12700E can manage up to 50K terminals
  • C. Asingle CloudEngine S12700E can manage up to 10K APs
  • D. CloudEngine S12700E supports PoE

Answer: D

Explanation:
Explanation
CloudEngine S12700E does not support PoE. PoE is a technology that allows network devices to receive power from data cables instead of power cables. PoE is usually used for access switches that connect to devices such as IP phones and wireless APs, but not for core switches such as CloudEngine S12700E. A single CloudEngine S12700E can manage up to 10K APs by integrating native WLAN AC capabilities4. A single CloudEngine S12700E can manage up to 50K terminals by using free mobility feature that ensuresconsistent user experience across wired and wireless networks4. CloudEngine S12700E integrates hardware-based OAM/BFD to provide fast fault detection and location for various services such as Ethernet, IP, MPLS, and VxLAN


NEW QUESTION # 81
In OceanStor Dorado V6, one LUN is enough for testing close-to-maximum performance.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 82
Which are the key technologies of SmartMatrix 3.0? (Multiple Choice)

  • A. Back-end Interconnect I/O Module (BIM)
  • B. FC Front-end Interconnect I/O Module (FC FIM)
  • C. Continuous cache mirroring
  • D. iSCSI and NAS FIM

Answer: A,B,C


NEW QUESTION # 83
Which of the following are benefits of front-end interconnect (shared) I/O modules? (Multiple choice)

  • A. Storage sysadmins are needed to ensure the multipath software in servers runs online before controller upgrades.
  • B. Host path loss prevention in the event of controller failure, controller hard/software upgrades, and even single FC 1 between host and storage.
  • C. Fewer front-end modules and host links needed.
  • D. Direct data dispatch to the distributed controllers through front-end modules in one controller enclosure.

Answer: B,C


NEW QUESTION # 84
Which of the following statements about basic concepts in data center network is incorrect?

  • A. Spine nodes are core nodes on the fabric network. They provide high-speed IP forwarding and conned to leaf nodes using high-speed interfaces in any scenario, spine nodes do not need to support VXLAN
  • B. The underlay network is a bearer network consisting of various physical devices, such as TOR switches, aggregation switch core switches, load balancing devices and firewalls
  • C. A leaf node is a fabric network function access node and provides various network devices to access a VXLAN network
  • D. The overlay technology is a tunnel encapsulation technology, such as VXLAN The basic principle is that packets are encapsulated in tunnel encapsulation mode, transparently transmitted on the underlying network, and then decapsulated to obtain original packets after reaching the destination. This is equivalent to a network overlay (overlay) on the underlying network.

Answer: A

Explanation:
Explanation
Spine nodes are core nodes on the fabric network, but they do need to support VXLAN in some scenarios.
According to the Data Center Networking: What It Is, Why It Matters, And Types article, VXLAN is a tunnel encapsulation technology that allows overlay networks to be created on top of the underlay network. Spine nodes need to support VXLAN when they act as gateways between different overlay networks or between overlay and underlay networks.


NEW QUESTION # 85
Oceanstor Dorado V6 series includes entry-level mid-range and high-end product models.

  • A. False
  • B. True

Answer: B


NEW QUESTION # 86
Which of the following models supports expansion of up to 32 controllers?

  • A. OceanStor Dorado 3000 V6
  • B. OceanStor Dorado 5000 V6
  • C. OceanStor Dorado 6000 V6
  • D. OceanStor Dorado 18000 V6

Answer: D


NEW QUESTION # 87
Which of the following statements about NE8000 M14 is incorrect?

  • A. Can be deployed in a 300 mm-deep cabinet
  • B. Various features: L2/L3 VPN, EVPN. SRv6 and BUG
  • C. Control unit and forwarding unit are physically separated
  • D. Key components redundancy

Answer: A

Explanation:
Explanation
NE8000 M14 cannot be deployed in a 300 mm-deep cabinet. According to the Huawei NetEngine 8000 M14 Routers Support Guide1, the NE8000 M14 requires a cabinet with a depth of at least 800 mm.


NEW QUESTION # 88
Which statements are true about the benefits of deduplicatin and compression provided by FusionStorage? (Multiple choice)

  • A. Extending the SSD service life.
  • B. Reducing the TCO
  • C. Reducing the initial storage purchase cost.
  • D. Saving storage space.

Answer: B,C,D


NEW QUESTION # 89
How many controllers can be concurrently accessed by a single SSD in OceanStor Dorado V6 high-end storage?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A


NEW QUESTION # 90
Which is NOT a typical application of HyperMetro for SAN?

  • A. Oracle RAC application
  • B. SAP HANA application (in application mode)
  • C. SQL Server application
  • D. VMware vSphere application

Answer: B


NEW QUESTION # 91
HyperMetro uses the quorum server mode. If all replication links between two sites are down, what are the Health Status, Running Status, and Link Status of the HyperMetro pair?

  • A. Faulty, To be synchronized, Link down
  • B. Faulty. Normal. To be recovered
  • C. Abnormal, Faulty. ...

Answer: C


NEW QUESTION # 92
......

Try Best H19-338 Exam Questions from Training Expert Exam-Killer: https://www.exam-killer.com/H19-338-valid-questions.html

Practice Examples and Dumps & Tips for 2023 Latest H19-338 Valid Tests Dumps: https://drive.google.com/open?id=1-F0i9kL_KMCi2jRvNUVnH4Rn6vh9qshG