NEW QUESTION 84
A Windows client using the SMB protocol is trying to access a multiprotocol file system from a Dell Unity XT NAS server. The local group database was checked and no mapping was found.
What is the next step in the SID to UID resolution process?

  • A. Secmap is checked
  • B. The Windows user access is removed
  • C. The domain controller is checked
  • D. The Windows user is mapped to the default UNIX account

Answer: C

Explanation:
Explanation
When a Windows client uses the SMB protocol to access a multiprotocol file system from a Dell Unity XT NAS server, the SID (Security Identifier) of the Windows user is mapped to a UID (User Identifier) on the UNIX file system. If no mapping is found in the local group database, the domain controller is checked to see if the SID is present there. The domain controller can provide the information needed to map the SID to the corresponding UID on the file system, allowing the Windows user to access the files. If the SID is not present in the domain controller, the Windows user's access would be removed.

 

NEW QUESTION 85
A customer updates SCOS to the latest version. They see a popup window in DSM about a Spare Optimizer. They ask you what the significance is of this notification concerning changes to the system.
How should you respond?

  • A. Health check verifies sufficient I0 across all drives. All drives are converted to Hot Spare Disks. User data is written to all I/0 drives.
  • B. Health check verifies sufficient spare space across all drives. Hot spares are converted to Managed Disks. User data is written to newly available l/0 drives.
  • C. Health check verifies sufficient drives for hot spares. Some drives are converted to Hot Spare Disks. User data is written to only I/O drives.
  • D. Health check verifies sufficient spare space across hot spare drives. Hot spares are converted to Optimized Disks. User data is written to newly available /O drives.

Answer: A

 

NEW QUESTION 86
Match each Dell EMC Unity feature with its destination.

Answer:

Explanation:

Reference:
https://www.delltechnologies.com/resources/en-us/asset/white-papers/products/storage/h15572- dell_emc_unity-nas_capabilities.pdf

 

NEW QUESTION 87
To which bus is the Dell EMC Unity 880F DPE connected?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

Explanation:
Explanation/Reference: https://www.delltechnologies.com/resources/en-us/asset/white-papers/products/storage/ h17782-dell-emc-unity-xt-introduction-to-the-platform.pdf

 

NEW QUESTION 88
How are vVol datastores mounted in Dell EMC PowerStore storage during the creation of vVol datastores in the vSphere environment shared by ESXi hosts?

  • A. VMFS datastores
  • B. Volume Groups
  • C. Storage containers
  • D. Storage Groups

Answer: C

 

NEW QUESTION 89
A customer is running an Exchange environment on Dell EMC SC Series arrays and would like to leverage application consistent snapshots.
What would meet the customer requirements?

  • A. Consistent Snapshots
  • B. Replay Manager
  • C. Parallel Snapshots
  • D. Volume Shadow Copy

Answer: B

 

NEW QUESTION 90
You are designing a Dell EMC SC Series solution that will be optimized for IOPS.
What is a key consideration?

  • A. RAID efficiency
  • B. Read/write ratio
  • C. Deduplication ratio
  • D. Compression ratio

Answer: D

 

NEW QUESTION 91
What is achieved by adding a top tier of SSDs when designing a Dell Unity XT hybrid solution with FAST VP and FAST Cache?

  • A. Provides an additional data redundancy layer
  • B. Isolates file top-talkers I/O from block data I/O
  • C. Helps keep paged metadata on FLASH media
  • D. Improves compression space efficiencies

Answer: C

Explanation:
Explanation
FAST VP (Fully Automated Storage Tiering for Virtual Pools) and FAST Cache (Fully Automated Storage Tiering for Cache) are features that allow you to optimize the performance of your storage by automatically moving data between different storage tiers based on usage patterns. The SSD tier is used to store frequently accessed metadata, such as file system structures, directories, and inode tables, which are accessed frequently and are small enough to fit in the SSD cache. Keeping paged metadata on flash media improves the overall system performance, as it allows for faster access to the metadata, reducing the latency and the number of I/O operations needed to access it.

 

NEW QUESTION 92
A company has a Dell Unity XT 880 at its Boston site providing file storage for a business production application The company has a second remote site 8 km (5 mi) away in Cambridge A third site is in New York (342 km (213 mi) from the Boston site) How can the same production data be protected against system outage with a zero RPO and a maximum of 15 minutes RPO data recovery?

  • A. Asynchronous replicate from Boston to Cambridge Asynchronous replicate from Cambridge to New York
  • B. Synchronous replicate from Boston to Cambridge Synchronous replicate from Boston to New York
  • C. Synchronous replicate from Boston to Cambridge Asynchronous replicate from Boston to New York
  • D. Synchronous replicate from Boston to Cambridge Synchronous replicate from Cambridge to New York

Answer: B

Explanation:
Explanation
Synchronous replication will provide a zero RPO as all data is written to both the primary and secondary storage at the same time, which means any data written to the primary storage will be instantly available on the secondary storage. This configuration will ensure that the data is protected against system outage, and in case of any failure, the recovery time will be a maximum of 15 minutes as the data is already replicated to the secondary site.

 

NEW QUESTION 93
Which SAS SSDs are supported by Dell EMC PowerStore?

  • A. 1920 GB, 3840 GB, and 7680 GB only
  • B. 960 GB, 1920 GB, and 3840 GB only
  • C. 1920 GB, 3840 GB, 7680 GB, and 15360 GB
  • D. 960 GB, 1920 GB, 3840 GB, and 7680 GB

Answer: A

Explanation:
Explanation
3.4.4 SAS SSD

 

NEW QUESTION 94
A storage administrator wants to do a tech refresh from a legacy EQL system to a new Dell EMC SC Series array. What is needed to correctly size the new array?

  • A. Peak IOPS information
  • B. Contract support end date
  • C. Storage tiers
  • D. Latency

Answer: A

Explanation:
https://downloads.dell.com/manuals/common/sc-series-performance-availability-best-practices-dell-emc-4024-bp-sc_en-us.pdf (1.9 Sizing an SC Series array for performance requirements - pag.9)

 

NEW QUESTION 95
drag to right to correct sep.

Answer:

Explanation:

Explanation
Diagram Description automatically generated

 

NEW QUESTION 96
A customer has a Dell EMC SC9000 array with six SC420 enclosures running SCOS 7.3.
The enclosure configuration is as follows:
- Two enclosures have write-intensive SSDs
- Four enclosures have read-intensive SSDs
What is recommended as a general guideline for making spare drive assignments?

  • A. 2 spares per drive type per array
  • B. 1 spare per drive type per shelf
  • C. 2 spare drives per shelf
  • D. Dedicated spares are not required

Answer: D

 

NEW QUESTION 97
A Dell EMC Unity storage administrator needs to build a NAS server configuration to support failover between SPs and NAS resources. What is a term for this configuration?

  • A. LACP
  • B. Local Replication
  • C. Separate IP Switches
  • D. IP Multi-tenancy

Answer: B

Explanation:
Explanation/Reference: https://www.delltechnologies.com/en-ae/documentation/unity-family/unity-p-replication- config/02-unity-rep-br-workflow.htm

 

NEW QUESTION 98
What is a characteristic of tenant traffic on a Dell EMC Unity array?

  • A. Separated by one associated VLAN providing data separation with increasing security at the Linux Kernel layer
  • B. Separated by the associated subnet providing data separation with increasing security at the network layer
  • C. Separated by the associated subnet at the Linux Kernel layer
  • D. Separated by the associated VLANs at the Linux Kernel layer

Answer: B

 

NEW QUESTION 99
How are vVol datastores mounted in Dell EMC PowerStore storage during the creation of vVol datastores in the vSphere environment shared by ESXi hosts?

  • A. VMFS datastores
  • B. Volume Groups
  • C. Storage containers
  • D. Storage Groups

Answer: C

Explanation:
Explanation
A storage container is used to present vVol storage from a PowerStore cluster to vSphere. vSphere mounts the storage container as a vVol datastore and makes it available for VM storage. When a PowerStore cluster is used to provide VM storage, user VMs should be provisioned on the vVol datastores. The default storage container is mounted automatically on the nodes of the cluster.

 

NEW QUESTION 100
A customer wants to provision a file system while creating a NAS server in a Dell EMC PowerStore T system. What information is needed to create the NAS server?

  • A. Subnet
  • B. DNS details
  • C. WWPN
  • D. FQDN

Answer: B

Explanation:
Reference:
https://topics-cdn.dell.com/pdf/pwrstr-cfg-smb_en-us.pdf

 

NEW QUESTION 101
Which are benefits of choosing the highest capacity flash drives when designing a Dell Unity XT All-Flash system?

  • A. Enhances data security and system boot time
  • B. Lowers physical space power and cooling requirements
  • C. Decreases ware-leveling, performance and redundancy requirements
  • D. Reduces maintenance and rebuild time

Answer: B

Explanation:
Explanation
Choosing the highest capacity flash drives when designing a Dell Unity XT All-Flash system can provide several benefits, including lower physical space, power and cooling requirements. Additionally, higher capacity drives can also improve system boot time, reduce maintenance and rebuild time, and decrease wear-leveling, performance, and redundancy requirements.

 

NEW QUESTION 102
What is a feature of Dell EMC Unity unified snapshots?

  • A. Redirect on Write
  • B. Copy on First Write
  • C. Copy on First Access
  • D. Delta set extension

Answer: A

 

NEW QUESTION 103
A customer sales order lists M.2 Devices as a line item. The order is for a Dell EMC Unity 380F array. How many M.2 Devices should appear in the order?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 104
A Dell PowerStore administrator has been asked to create a NAS file sharing environment for several clients.
The clients will be running either Linux (NFS) or Windows (SMB) and must have access to the same data simultaneously How can this be achieved using Dell PowerStore?

  • A. Configure a snapshot rule and protection policy and apply it to the file system
  • B. Configure multiprotocol access to required file system
  • C. Configure file data to be replicated for access by different client types
  • D. Configure two NAS servers place all Linux data in one and all Windows data in the other

Answer: B

Explanation:
Explanation
Dell PowerStore allows you to create a NAS file sharing environment for several clients by configuring multiprotocol access to the required file system. This means that the same file system can be accessed by both Linux and Windows clients using either the NFS or SMB protocols. This can be achieved by creating a file system, and configuring it to allow access using both the NFS and SMB protocols. Once the file system is set up, you can assign permissions and share the file system with the appropriate clients. This way, the clients will be able to access the same data simultaneously, regardless of whether they are running Linux or Windows and which protocol they are using. It's not necessary to replicate data for access by different client types, it would be an extra step that would consume more resources and would be unnecessary

 

NEW QUESTION 105
What is a feature of Dell EMC Unity unified snapshots?

  • A. Redirect on Write
  • B. Copy on First Write
    Reference; https://www.delltechnologies.com/en-ba/collaterals/unauth/white-papers/products/storage/h15089- dell_emc_unity-snapshots_and_thin_clones.pdf (7)
  • C. Copy on First Access
  • D. Delta set extension

Answer: A

 

NEW QUESTION 106
A customer has a Dell EMC SC9000 array with six SC420 enclosures running SCOS 7.3. The enclosure configuration is as follows:
* Two enclosures have write-intensive SSDs
* Four enclosures have read-intensive SSDs
What is recommended as a general guideline for making spare drive assignments?

  • A. 2 spares per drive type per array
  • B. 1 spare per drive type per shell
  • C. 2 spare drives per shell
  • D. Dedicated spares are not required

Answer: D

Explanation:
Explanation
"SCOS 7.3, Distributed Sparing: eliminates the need for dedicated spares by giving customers the option to distribute sparing capacity across all drives in the array."

 

NEW QUESTION 107
What is a characteristic of tenant traffic on a Dell EMC Unity array?

  • A. Separated by one associated VLAN providing data separation with increasing security at the Linux Kernel layer
  • B. Separated by the associated VLANs at the Linux Kernel layer
  • C. Separated by the associated subnet at the Linux Kernel layer
  • D. Separated by the associated subnet providing data separation with increasing security at the network layer

Answer: B

 

NEW QUESTION 108
In Dell EMC Power Store storage, if the remote cluster has multiple appliances, then what automatically chooses the destination appliance for the resource?

  • A. Master appliance
  • B. Resource Balancer
  • C. Source array
  • D. Performance Policy

Answer: B

 

NEW QUESTION 109
......

Get Latest DES-1D12 Dumps Exam Questions: https://drive.google.com/open?id=13cNZCxVbAP5e3jmpPsa0Zbh9SWxTCKGo

Full DES-1D12 Practice Test and 152 unique questions with explanations waiting just for you, get it now: https://www.exam-killer.com/DES-1D12-valid-questions.html