NEW QUESTION # 88
Which custom poller can display the poller results as a chart, gauge, or table?
- A. hardware health
- B. network insight
- C. universal device poller (UnDP)
- D. device studio poller
Answer: C
NEW QUESTION # 89
If a NetFlow collector service is showing a "down" status, which two of the following steps are possible troubleshooting options? (Choose two.)
- A. Confirm the database connection is up and server has free resources.
- B. Start or restart SolarWinds' NetFlow service from Orion service manager.
- C. Start or restart SolarWinds' collector service.
- D. Delete and re-add NetFlow collector service.
Answer: A,B
NEW QUESTION # 90
After creating a new device studio poller that appears to be returning values on a test device, it is then applied to additional nodes. One of these new devices is not returning the statistics of the test node. Which two of the following reasons might be the cause of the issue? (Choose two.)
- A. communication issue exists in new device
- B. object IDs (QIDs) are not supported
- C. new device needs to be rebooted
- D. devices have different firmware versions
Answer: B,D
NEW QUESTION # 91
Which three of the following setting can be used to customize the thresholds for an object in SolarWinds' platform? (Choose three.)
- A. single poll
- B. X concurrent polls
- C. X consecutive polls
- D. X of Y polls
Answer: B,C,D
NEW QUESTION # 92
Network wide node and interface changes were recently made to several fields including names and IP addresses on nodes, captions, and aliases for their interfaces. Those changes are not updated in the hybrid cloud observability web console, even if a new polling is forced.
What should be done to resolve the issue?
- A. Run a rediscovery on both nodes and interfaces to refresh the data.
- B. Run a rediscovery on the node, which will also update the interfaces.
- C. Delete and re-add each of the nodes and their interfaces.
- D. Manually update the changed information in each poller.
Answer: A
NEW QUESTION # 93
What is required to submit an MIB database update request to SolarWinds?
- A. SNMP or MIB walk from the device
- B. specific object ID (QID) for polling
- C. type of widget to populate data
- D. polling interval to monitor the metric
Answer: A
NEW QUESTION # 94
Which two of the following components are required to successfully create a NetPath probe? (Choose two.)
- A. connection port
- B. Linux agent
- C. Windows agent
- D. source IP address
Answer: A,C
NEW QUESTION # 95
The status of the interfaces for a network switch shows as "unknown" in SolarWinds' platform web console, although the node status is "up". What could be the reason?
- A. hardware sensors are disabled on the node
- B. interfaces are not managed in hybrid cloud observability (HCO)
- C. interface details have changed on the device
- D. ICMP is blocked between the node and the polling engine
Answer: C
NEW QUESTION # 96
An agent is deployed to the Windows server in order to monitor logs, however logs are not coming in from the related agent. It is confirmed that the agent software is deployed and installed on the target machine.
What additional setting needs to be checked?
- A. polling method is set to WMI
- B. polling method is set to agent
- C. correct rule to read logs is configured
- D. log forwarding feature is enabled
Answer: C
NEW QUESTION # 97
Which three of the following flow protocols does hybrid cloud observability support? (Choose three.)
- A. J-Flow
- B. NetFlowv9
- C. NetFlowv6
- D. sFlow
Answer: A,B,D
NEW QUESTION # 98
A node has been added to hybrid cloud observability and shows an "unknown" status until the data is polled.
The default interval for polling status is two minutes.
If the node stays in the "unknown" status longer than the polling interval, which three of the following steps can be performed to resolve the issue? (Choose three.)
- A. Verify the appropriate polling method is set for this node.
- B. Run SNMP walk on the appropriate node.
- C. Ping device from assigned polling engine.
- D. Verify a pingresponsefor this node is received through the ICMP.
Answer: A,C,D
NEW QUESTION # 99
An existing NetPath probe is examined, and it is noted that the thickness of connection lines is different on various routes between devices. What does this indicate?
- A. The thicker line is monitored in hybrid cloud observability (HCO) and contains other metrics.
D Two probes with different probing intervals are monitoring the same path - B. The thicker line indicates the more likely path of traffic from source to destination.
- C. The probing interval for the probe is shorter on one path than on the other.
Answer: B
NEW QUESTION # 100
In which scenario would the device studio poller tool be considered the best tool for building a required poller?
- A. Building a poller to add missing information to node details.
- B. Building a poller for ARP tables to display in the web console.
- C. Building a poller to monitor VPN tunnel status.
- D. Building a poller to show CPU and memory status.
Answer: A
NEW QUESTION # 101
A universal device poller (UDP) is being built for a metric to monitor in a radial gauge of a web console.
When a gauge resource in the poller is to be selected, it is found that the resource is grayed out. What could be causing this?
- A. UDP does not support gauges to display polled information.
- B. OID polled is not supported by the device.
- C. object ID (OID) polled does not support radial gauge.
- D. OID polled is not in current MIB file of MIB database.
Answer: C
NEW QUESTION # 102
What can be done to display the average CPU utilization of a node in a web console widget, if the device studio poller returns a table of multi-core CPU utilizations?
- A. Display the returned table of values in the web console widget and manually calculate the average.
- B. Contact the device vendor to provide an SNMP object ID (OID)forthe averaqe CPU utilization statistic.
- C. Select the add calculated value option and use the average function for returned values.
- D. Configure the web console widget to calculate the average of the returned table values.
Answer: C
NEW QUESTION # 103
What is the default amount of historical data needed for calculating capacity forecast?
- A. 7 to 30 days
- B. 7 to 180 day
- C. 1 to 30 days
- D. 1 to 90 days
Answer: B
NEW QUESTION # 104
A device studio poller is being built for node detail information. For the values supported, it has been decided to enter textual values instead of object IDs (OIDs). Which statements is true?
- A. If the textual value changes, it will update automatically.
- B. Only textual values can be used for host names, all other values must be OlDs.
- C. If the textual value changes on the node, the poller must be manually updated.
- D. If the textual value is misspelled, it will not poll correctly.
Answer: C
NEW QUESTION # 105
What can be done to show the description of an object ID (OID)?
- A. Download the latest OlD.cfq from customer portal.
- B. Contact vendor to obtain the latest SNMPwalk.
- C. Perform an SNMPwalk on the tarqet device.
- D. Update the MIB database via SolarWinds support.
Answer: C
NEW QUESTION # 106
The status of the parent node of several interfaces is showing red. It is determined that several operationally down and administratively shutdown interfaces are included for monitoring of the parent node.
Which menu in the node details summary page of SolarWinds' platform allows users to remove interfaces that are operationally down and administratively shutdown?
- A. edit node
- B. polling settings
- C. List resources
- D. add alert
Answer: C
NEW QUESTION # 107
Which three of the following are effects of enabling the "resolve IPv4 and IPv6 addresses to DNS hostname" option and disabling the "resolve and store IPv4 hostname immediately when a flow record is received" option? (Choose three.)
- A. DNS names will not be displayed on top domain resources/reports
- B. amount of database space used to store received flows is reduced
- C. number of reads/writes on SQL server linked to name resolution is reduced
- D. amount of database memory used to store DNS information is reduced
Answer: A,C,D
NEW QUESTION # 108
It is noted that the hardware health monitoring for a Cisco switch is generating false positives. It is verified that the alerted hardware issues are not occurring. What is causing the issue?
- A. Modify the widget thresholds to filter out the false positives.
- B. MIB on the device is notthe preferred MIB that is beingpolled.
- C. Restart SNMP on the device to refresh the hardware statistics.
- D. Hardware sensors were incorrectly assigned to another switch.
Answer: B
NEW QUESTION # 109
......
Guaranteed Success with Hybrid-Cloud-Observability-Network-Monitoring Dumps: https://www.exam-killer.com/Hybrid-Cloud-Observability-Network-Monitoring-valid-questions.html
Pass SolarWinds Hybrid-Cloud-Observability-Network-Monitoring Exam – Experts Are Here To Help You: https://drive.google.com/open?id=1b-4PoJnvx4TqzmCWNXhG6i-9iIrInIuE